financialsilikon.blogg.se

Onsip provisioning polycom 411
Onsip provisioning polycom 411











onsip provisioning polycom 411
  1. #Onsip provisioning polycom 411 how to
  2. #Onsip provisioning polycom 411 software
  3. #Onsip provisioning polycom 411 password

Resolution On a computer on the same network as the phone, browse to the phone's IP address.

#Onsip provisioning polycom 411 how to

How to Provision a Polycom VVX D230 through the Web GUI. If you want to log into your IP phone's Web Interface then use the value in the "Password field" on the Web Interface login screen (Username is not changed in the Phone's Web Interface, it remains as its default value -admin- even after provisioning).

#Onsip provisioning polycom 411 password

If the default Polycom password of 456 does not work, or if someone has changed the admin password on the phone, please do the following: Find and write down the MAC address (serial number) of the phone you want to reset. If you are resetting a Megapath phone, you may have been provided with a password by your Project Manager or support agent. Register with an LDAP Directory Server You can register your G7500 system with an LDAP directory server. Customer shall be responsible for ensuring the security and confidentiality of all User IDs.

onsip provisioning polycom 411

Managing Polycom Studio with Polycom Companion - IP Phone. The config they receive does not contain any sensitive data unless we have marked the handset as insecure - something we only do if moving the phone to a different user etc.Select User Name and enter your Lync username (same as step 3) Select Password and enter your password The rest of the fields can be left blank Select Sign In Sign-in via Polycom Web Sign-In Introduction. if you don't mention it in the config file it remains unchanged.Īll our other handsets check for config changes every 6 hours (+ random delay). If it isn't I will have to treat polycom handsets differently and only the phones to be push provisioned.Īll the other makes/models that I provision are additive or replacement config elements only. What I am asking is simply is it possibile to omit sensitve data from a config without the "user" (or line) being removed. If I omit the user/pass attributes the phone removes the "user". If I omit the reg section in the Polycom configs, when the phone provisions it removes the "user". This means that sensitive data is only available to the first request from when a handset was set to "insecure". When it is "secure" we omit the authentication and any other sensitive data from the config files. When a handset is not "secure" we hand out username and password details in our phone configs. Hi Stefan - I'm not sure if I can explain it any simpler - we define a handset as secure when it has provisioned with a username and password for the first time (or after a timeout period from when it was set to insecure.)

onsip provisioning polycom 411

If the polycom cannot work this way I just need to know so I can develop a one of sync-now only solution for the Polycoms. Instead we set our other handsets up to sync periodically with random offsets. but without having to send a config-sync SIP NOTIFY to all handsets - which would create major problems with simultaneous requests from 1000s of handsets.

onsip provisioning polycom 411

The reasons for wanting to send a config file without usernames/passwords in are it allows on the fly changes - such as speed dials, feature codes, wall paper changes etc. I'm provisioning, from an internet facing platform, several thousand handsets of many different makes and models and it is only the Polycoms that I am struggling with to do this particular requirement. My testing so far indicates that the config file is 100% destructive - any settings not defined are effectively erased so if I omit the username/password, or the entire reg section for a line, the "user" is removed (it logs this via syslog) What I want to know is if there is anyway to do this in the polycom provisioning files. This engine knows if a handset is in "secure" mode or not and if not it gives out the username and password. My config files are created on the fly by a templating engine. I don't have a problem - I just don't want my config file to contain usernames and password - all the time. Please ensure to provide some feedback if this reply has helped you so other users can profit from your experience. Also does your server support a SIP CHECK-SYNC ? You may want to attach some of the configuration you tested.

#Onsip provisioning polycom 411 software

Question: How can I find out my SIP or UC Software Version of my Phone? Therefore the Polycom VoIP FAQ contains this post here: In addition providing us with this basic information gives Polycom an idea what Software Versions are used in the field and avoids wasting time trying to troubleshoot issues which have already been addressed. The above is also stated in the "Must Read First" and is the absolute minimum requirement every new post should include. This also allows yourself and others to check against current software release notes, Administrator Guides or FAQ post’s. It is always useful to include the currently used SIP or UC Software version as issues experienced or a question asked may already be addressed in a newer release.













Onsip provisioning polycom 411